Hi

 

its  not a trick but , The way we understand the PCR even I got the same issue in current project

 

1. Firstly we should check PCR Grouping of the wage types in the input table 9000 and 9400

 

2. The PCR

 

3

 

9400

 

AMT?0

 

>

ADDWT *

 

*

AMT+ 9000

 

ADDWT *

 

 

Here , When you are Querying amount of WT9400 , System will read only amount from wage type 9400 and passes to output table OT, in such cases AMT+ 9000 or AMT=  9000 will not work

 

Instead ,  give ZERO=   RNA

 

Just like

 

3

 

9400

 

AMT?0

 

>

ADDWT *

 

*

ZERO=  RNA

AMT+E  9000

ADDWT *

 

Else , you can store the amount of 9000 in a variable table pass it to 9400 accordingly.

 