Quantcast
Channel: SCN: Message List
Browsing all 9129 articles
Browse latest View live

Re: RPUTPR00 - Run after change in Daily Work Schedule

Hi, From my point of view, when you don't get reply means either the case is strange or no body get the issue. I recommend to share screenshots of system to clarify the case.I got what you have done...

View Article


Re: Is it possible to customize OData response after Create

We have SAP_GWFND 740 SP 05.The Status would be 201 and not 200. My mistake and sorry for that. However if you see still the behavior is same.Behavior which we are seeing is,When Create operation is...

View Article


Re: LSMW not capturing user confirmation pop up for "Redetermine...

Its VA12.Changing Ship to party.

View Article

Re: Custom payslip is not displaying in ESS

HI Siddharth, My custom payslip has a logo on R3 it is displaying in R3, i configured properly in ESS, but all are displaying properly but when i except Logo and the columns also in payslip is not...

View Article

Re: FI GL Line item BEx Query to display only open line items

You just need to create 2 selections and restrict one with status = open, posting date and other with status = closed, posting date. Include posting date, accounting doc numberin the drilldown. As you...

View Article


Unable to fetch data from infoset and Composite infoprovider from BW into BPC

HiWhen I am trying to validate data from BW from infoset or Composite info provider I am facing problem In BPC.Is there any possibility to load the data from the SAP BW Infoset and Composite...

View Article

Re: steps required moving data sources from ECC dev to ECC quality other than...

Hi, For LO data source transports, down time is mandatory if data flow in prod.if not then sure your existing delta will be corrupted and will loss delta records. if  you clear explain your issue we...

View Article

Re: Write single data within Loop

  REPORT  ztest_scn.TYPES: BEGIN OF ty,         a(10) TYPE c,         b TYPE i,        END OF ty.DATA: a1(10) TYPE c,      a2(10) TYPE c,      b1 TYPE i,      b2 TYPE i.DATA: wa TYPE ty,      wa1 TYPE...

View Article


Re: SAPOSS-rfc connection error

Hi Raj, could you please try to add the saproute host name (instead of using IP, in case you are using public IP). MSHOST =/H/<hostname>/S/sapdp99/H/<sap ip>/S/sapdp99/H/oss001RegardsSunil

View Article


Re: issue regarding RG23D debit in service order issue against 261 movement type

When I am going to J1IJ & select material document it displays all the material.Again  I have to go that particular line item & select excise invoice & click on enter but here I have to go...

View Article

Re: Netweaver 7.02 trial install error

Hi Hara, May be you upload the full dump once before suggesting you anything. Regards,

View Article

Re: SLT replication issue...Need help to understand the issue

Hi Jyotsna, Thanks for your replay. Yes we are facing some problem during replication of T006A table. Mean time can you help me to understand the following:...

View Article

Re: 0ic_C03 Master data source?

Hi Vikarm, You can get lot of information on google check with cube name.  http://help.sap.com/saphelp_nw70/helpdata/en/4a/7a794f26a7687be10000000a421138/frameset.htm Regards,Ganesh Bothe

View Article


Report development

Dear Gurus, I need to develop a report in Bex analyser. My requirement is as blow. 1. Pull VEBLN from VBAK table on some condition.2. Pull VEBLN from VBFA table on the basis of VEBLN of VBAK table.3....

View Article

Re: Seperate Number Range for MATD Doc type in J1is Tcode

Could you share your Excise Part 2 screen shot of both 101 and 122 Mvt types. In addition, you can have a seperate Series group and define number range for Vendor return process and have used it in...

View Article


Re: HANA HA test cases

unbind the network IP and test it. Killing of sapstartsrv & sapstart will give the same impact of HDB stop You can also create some data in master node and check if it is there in slave....

View Article

Re: Does an higher reuse count value from sp_monitorconfig indicates to...

Rajesh, In simple sense ideally you should have the number of open objects = sp_countmetadata "open objects" +(plus) 10-20% more as this needs to be opening and using connections for the other...

View Article


BW report creation on IA03 transaction based on Operation and Inspection...

I have to create a BW report for Equipment Task List based on standard ECC transaction IA03. I am looking for a link to join two tables - PLPO and PLMK to get data for 'Operation/Activities' and...

View Article

Re: not showing in P&L Report

Hi Kindly post the problem with Screen shot for experts better understanding. With Regards  Balaji

View Article

Re: relating to sap co

Hi 1.how many operations can assign to the one work center? ... 6 operations2.what is the production order cycle ?....Mentioned by Rajneesh

View Article
Browsing all 9129 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>